mirror of
https://git.gfz-potsdam.de/naaice/iphreeqc.git
synced 2025-12-16 16:44:49 +01:00
Added documentation for electro-migration at top of RELEASE.TXT file.
git-svn-id: svn://136.177.114.72/svn_GW/phreeqc3/branches/concrete@12547 1feff8c3-07ed-0310-ac33-dd36852eb9cd
This commit is contained in:
parent
2e0a8a5121
commit
78734c68e6
126
RELEASE.TXT
126
RELEASE.TXT
@ -1,5 +1,74 @@
|
|||||||
Version @PHREEQC_VER@: @PHREEQC_DATE@
|
Version @PHREEQC_VER@: @PHREEQC_DATE@
|
||||||
|
|
||||||
|
The effect of an electrical field on multicomponent diffusion (electro-migration) is
|
||||||
|
calculated with the Nernst-Planck equation if one of the 2 column end-cell solutions has
|
||||||
|
a potential different from 0 (SOLUTION 0, SOLUTION cells + 1). For examples of electro-
|
||||||
|
migration, see http://www.hydrochemistry.eu/exmpls/electro_dif.html.
|
||||||
|
|
||||||
|
A number of new features have been implemented for electro-migration.
|
||||||
|
|
||||||
|
(1) The electric potential can be defined in keyword SOLUTION:
|
||||||
|
|
||||||
|
SOLUTION 1
|
||||||
|
-potential 3 # Volt
|
||||||
|
|
||||||
|
|
||||||
|
(2) The electric current in a column experiment can be defined in keyword TRANSPORT:
|
||||||
|
|
||||||
|
TRANSPORT
|
||||||
|
-current 1e-3 # Ampere
|
||||||
|
|
||||||
|
(3) When using -multi_d and -interlayer_d in TRANSPORT, the
|
||||||
|
porosity for calculating interlayer diffusion is added to the porosity
|
||||||
|
defined with -porosities or -multi_d. For example:
|
||||||
|
|
||||||
|
-porosities 0.3 0.29 0.28 ...
|
||||||
|
-multi_d true 1e-9 0.3 0.05 1.0 false
|
||||||
|
-interlayer_d true 0.07 0.01 250
|
||||||
|
|
||||||
|
The total porosities will be 0.37, 0.36, 0.35, ... in cells 1, 2, 3, ...
|
||||||
|
In previous versions, the interlayer porosity was subtracted from the porosity
|
||||||
|
defined with -multi_d.
|
||||||
|
|
||||||
|
(4) If the properties in a regular column (surface areas, lengths, double layers,
|
||||||
|
tortuosities, diffusion coefficients) are different for the two cells, the harmonic mean
|
||||||
|
is used for calculating the mass transfer (Appelo et al., 2010, Geochim. Cosmochim. Acta
|
||||||
|
74, 1201-1219).
|
||||||
|
|
||||||
|
(5) The following Basic functions have been added:
|
||||||
|
|
||||||
|
CURRENT_A # the current through the column, amps.
|
||||||
|
POT_V # potential in a cell, volts.
|
||||||
|
T_SC("Cl-") # The transport- or transference-number of the ion, equal to the
|
||||||
|
# fraction of the specific conductance contributed by the species(-).
|
||||||
|
VISCOS # At present, returns the viscosity of a pure water solution, same as
|
||||||
|
# VISCOS_0, milliPascal second.
|
||||||
|
VISCOS_0 # Returns the viscosity of a pure water solution at current conditions
|
||||||
|
# milliPascal second.
|
||||||
|
|
||||||
|
|
||||||
|
(6) A temperature damping factor and two parameters for ionic strength dependence were added for
|
||||||
|
the calculation of the diffusion coefficient of a solute species:
|
||||||
|
|
||||||
|
SOLUTION_SPECIES
|
||||||
|
H+ = H+
|
||||||
|
-dw 9.31e-9 763 0.46 1e-10
|
||||||
|
|
||||||
|
where the first number is the diffusion coeficient at 25 C, and the second number is a damping
|
||||||
|
factor for the temperature correction, as proposed by Smolyakov, according to Anderko and Lencka,
|
||||||
|
1997, Ind. Chem. Eng. Res. 36, 1932–1943:
|
||||||
|
|
||||||
|
Dw(TK) = 9.31e-9 * exp(763 / TK - 763 / 298.15) * TK * 0.89 / (298.15 * viscos).
|
||||||
|
|
||||||
|
The ionic strength correction is as follows:
|
||||||
|
Dw(I) = Dw(TK) * exp(-0.46 * DH_A * |z_H+| * I^0.5 / (1 + DH_B * I^0.5 * 1e-10 / (1 + I^0.75)))
|
||||||
|
|
||||||
|
---------
|
||||||
|
svn 12545
|
||||||
|
---------
|
||||||
|
PHREEQC: Added Basic function TITLE, which returns the last TITLE keyword definition (with
|
||||||
|
|
||||||
|
|
||||||
Version 3.3.11: March 10, 2017 (svn 12540)
|
Version 3.3.11: March 10, 2017 (svn 12540)
|
||||||
---------
|
---------
|
||||||
svn 12480
|
svn 12480
|
||||||
@ -30,8 +99,8 @@ Version 3.3.11: March 10, 2017 (svn 12540)
|
|||||||
svn 12439
|
svn 12439
|
||||||
---------
|
---------
|
||||||
PHREEQC: Error check that the same element name was not used for
|
PHREEQC: Error check that the same element name was not used for
|
||||||
both a SURFACE and and EXCHANGEr, which caused a NULL pointer. Some variables in the unknown
|
both a SURFACE and and EXCHANGEr, which caused a NULL pointer.
|
||||||
structure are now initialized.
|
Some variables in the unknown structure are now initialized.
|
||||||
|
|
||||||
---------
|
---------
|
||||||
svn 12319
|
svn 12319
|
||||||
@ -279,33 +348,44 @@ Version 3.3.5 (10806): February 3, 2016
|
|||||||
# mobile (here = 0.3) and immobile (here = 0.1) porosities
|
# mobile (here = 0.3) and immobile (here = 0.1) porosities
|
||||||
# defined with -stagnant are used.
|
# defined with -stagnant are used.
|
||||||
|
|
||||||
The electric potential can be defined in keyword SOLUTION:
|
---------
|
||||||
-potential 3 # Volt
|
svn 10770
|
||||||
|
---------
|
||||||
|
IPhreeqc: Added optional argument sl to GetSelectedOutputValue in Fortran. The revised method
|
||||||
|
is as follows, where sl is a new optional argument.
|
||||||
|
|
||||||
The effect of an electrical field on multicomponent diffusion (electro-migration) is calculated with
|
CHARACTER(LEN=40) :: sv
|
||||||
the Nernst-Planck equation if one of the 2 column end-cell solutions has a potential different from 0
|
status = GetSelectedOutputValue(id, i, j, vt, dv, sv, sl)
|
||||||
(SOLUTION 0, SOLUTION cells + 1). For examples of electro-migration, see
|
|
||||||
http://www.hydrochemistry.eu/exmpls/electro_dif.html
|
|
||||||
|
|
||||||
Added special BASIC functions for obtaining parameters calculated in electro-migration:
|
In the example, if the character string generated in IPhreeqc and stored in sv is 40 characters or
|
||||||
CURRENT_A # the current (A) through the column
|
less, the value of sl will be 0. If the character string generated in IPhreeqc was greater than
|
||||||
POT_V # potential (V) in a cell
|
40 characters, the truncated string is stored in sv, but the value of sl will contain the length
|
||||||
|
of the string before truncation.
|
||||||
|
|
||||||
If the properties in a regular column (surface areas, lengths, double layers,
|
---------
|
||||||
tortuosities, diffusion coefficients) are different for the two cells, the harmonic
|
svn 10668
|
||||||
mean is used for calculating the mass transfer (Appelo et al., 2010, Geochim. Cosmochim.
|
---------
|
||||||
Acta 74, 1201-1219).
|
All programs: Now using Jenkins for continuous integration.
|
||||||
|
|
||||||
A temperature damping factor was added for the temperature effect of viscosity on the diffusion
|
---------
|
||||||
coefficient of a solute species:
|
svn 10664
|
||||||
|
---------
|
||||||
|
PHREEQC: Erroneous input could cause a segmentation fault for surfaces
|
||||||
|
related to minerals or kinetics.
|
||||||
|
|
||||||
SOLUTION_SPECIES
|
---------
|
||||||
H+ = H+
|
svn 10644
|
||||||
-dw 9.31e-9 831 # Dw(TK) = 9.31e-9 * exp(831 / TK - 831 / 298.15) * TK * 0.89 / (298.15 * viscos)
|
---------
|
||||||
|
PHREEQC: Minor format change for specific conductance.
|
||||||
The equation was proposed by Smolyakov, according to Anderko and Lencka, 1997, Ind. Chem. Eng. Res.
|
|
||||||
36, 1932–1943.
|
|
||||||
|
|
||||||
|
---------
|
||||||
|
svn 10640
|
||||||
|
---------
|
||||||
|
PhreeqcRM: Advection example in C and C++ had wrong MPI type for integer transfers.
|
||||||
|
Example code in documentation also had wrong MPI type for some integer transfers.
|
||||||
|
Integer transfers in Fortran should use MPI_INTEGER, while integer transfers in
|
||||||
|
C and C++ should use MPI_INT.
|
||||||
|
|
||||||
---------
|
---------
|
||||||
svn 10632
|
svn 10632
|
||||||
---------
|
---------
|
||||||
|
|||||||
Loading…