Fixed units conversion bug in PhreeqcRM

git-svn-id: svn://136.177.114.72/svn_GW/phreeqc3/trunk@9937 1feff8c3-07ed-0310-ac33-dd36852eb9cd
This commit is contained in:
David L Parkhurst 2015-07-06 22:57:57 +00:00
parent b420cb7c09
commit b2d61c7797

View File

@ -1,5 +1,15 @@
Version @PHREEQC_VER@: @PHREEQC_DATE@
--------
svn 9930
--------
PhreeqcRM had a serious error in the convertion of units from transport
to themodule. The error occurred when using H2O as a component and mg/L
as the transport unit.
Version 3.2.0: June 10, 2015
--------
svn 9809
--------